Physical specifications |
● Usable rack space: 7RU
● 4-slot chassis: 2 dedicated supervisor modules and 2 I/O modules
● 4 power supply slots
● Dimensions (H x W x D): 12.2 x 17.3 x 24 in. (30.9 x 43.9 x 61 cm)
● Chassis depth including cable management and chassis doors is 29.6 in. (75.2 cm)
● Unit is rack mountable in a standard 19-inch (482.6-mm) Electronic Industries Alliance (EIA) rack
● Weight
◦ Chassis only: 45 lb. (20 kg)
◦ Fan Tray: 25 lb (11.3 kg)
● Supports 3-kW AC and DC and 3.5-kW HV AC/DC power supplies
● Supports up to 6 chassis stacked in a 42RU rack |
● Usable rack space: 14RU
● 9-slot chassis: 2 dedicated supervisor modules and 7 I/O modules
● 5 fabric module slots
● 2 power supply slots
● Dimensions (H x W x D): 24.5 x 17.3 x 24 in. (62.2 x 43.9 x 61 cm)
● Chassis depth including cable management and chassis doors is 29 in. (73.7 cm)
● Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack
● Weight
◦ Chassis only: 100 lb. (45 kg)
◦ Fabric Module: 5 lb (2.3 kg)
◦ Fan Tray: 25 lb (11.3 kg)
● Supports 6-kW and
7.5-kW AC and DC power supplies
● Supports up to 3 chassis stacked in a 42RU rack |
● Usable rack space: 21RU
● 10-slot chassis: 2 dedicated supervisor modules and 8 I/O modules
● 5 fabric module slots
● 3 power supply slots
● Dimensions (H x W x D): 36.5 x 17.3 x 33.1 in. (92.7 x 43.9 x 84.1 cm)
● Chassis depth including cable management and chassis doors is 38 in. (96.5 cm)
● Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack
● Weight
◦ Chassis only: 200 lb. (90 kg)
◦ Fabric Module: 4 lb (1.8 kg)
◦ System Fan Tray: 20 lb (9.1 kg)
◦ Fabric Fan Tray: 5 lb (2.3 kg)
● Supports 6-kW and
7.5-kW AC and DC power supplies |
● Usable rack space: 25RU
● 18-slot chassis: 2 dedicated supervisor modules and 16 I/O modules
● 5 fabric module slots
● 4 power supply slots
● Dimensions (H x W x D): 43.5 x 17.3 x 33.1 in. (110.5 x 43.9 x 84.1 cm)
● Chassis depth including cable management and chassis doors is 38 in. (96.5 cm)
● Unit is rack mountable in a standard 19-inch (482.6-mm) EIA rack
● Weight
◦ Chassis only: 187 lb. (85 kg)
◦ Fabric Module: 7.5 lb (3.4 kg)
◦ Fan Tray: 25.8 lb (11.7 kg)
● Supports 6-kW and
7.5-kW AC and DC power supplies |
Environmental specifications |
● Airflow direction: Side to rear
● Operating temperature: 32 to 104°F (0 to 40°C)
● Operational relative humidity: 5 to 90%, noncondensing
● Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
● Seismic: Zone 4 per GR63
● Floor loading: 42 lb. per sq. ft.
● Operational vibration
● GR63, Section 5.4.2
● ETS 300 019-1-3, Class 3.1, Section 5.5
● Storage altitude: -1000 to 30,000 ft.
● Storage temperature: -40 to 158°F (-40 to 70°C)
● Storage relative humidity: 5 to 95%, noncondensing
● Heat dissipation: Maximum 3500W per chassis (actual dissipation will be lower, depending on the chassis configuration) |
● Airflow direction: Side to side
● Operating temperature: 32 to 104°F (0 to 40°C)
● Operational relative humidity: 5 to 90%, noncondensing
● Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
● Seismic: Zone 4 per GR63
● Floor loading: 104 lb. per sq. ft.
● Operational vibration
● GR63, Section 5.4.2
● ETS 300 019-1-3, Class 3.1, Section 5.5
● Storage altitude: -1000 to 30,000 ft.
● Storage temperature: -40 to 158°F (-40 to 70°C)
● Storage relative humidity: 5 to 95%, noncondensing
● Heat dissipation: Maximum 7500W per chassis (actual dissipation will be lower, depending on the chassis configuration) |
● Airflow direction: Bottom front of chassis to top back
● Operating temperature: 32 to 104°F (0 to 40°C)
● Operational relative humidity: 5 to 90%, noncondensing
● Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
● Seismic: Zone 4 per GR63
● Floor loading: 190 lb. per sq. ft.
● Operational vibration
● GR63, Section 5.4.2
● ETS 300 019-1-3, Class 3.1, Section 5.5
● Storage altitude: 1000 to 30,000 ft.
● Storage temperature: -40 to 158°F (-40 to 70°C)
● Storage relative humidity: 5 to 95%, noncondensing
● Heat dissipation: Maximum 12,000W per chassis (actual dissipation will be lower, depending on the chassis configuration) |
● Airflow direction: Side to side
● Operating temperature: 32 to 104°F (0 to 40°C)
● Operational relative humidity: 5 to 90%, noncondensing
● Operating altitude: -500 to 13,123 ft. (agency certified 0 to 6500 ft.)
● Seismic: Zone 4 per GR63
● Floor loading: 190 lb. per sq. ft.
● Operational vibration
● GR63, Section 5.4.2
● ETS 300 019-1-3, Class 3.1, Section 5.5
● Storage altitude: 1000 to 30,000 ft.
● Storage temperature: -40 to 158°F (-40 to 70°C)
● Storage relative humidity: 5 to 95%, noncondensing
● Heat dissipation: Maximum 18,000W per chassis (actual dissipation will be lower, depending on the chassis configuration) |